{"id":822,"date":"2025-08-29T09:43:18","date_gmt":"2025-08-29T07:43:18","guid":{"rendered":"https:\/\/corona1.eu\/en\/?page_id=822"},"modified":"2025-08-29T09:44:23","modified_gmt":"2025-08-29T07:44:23","slug":"grounding-control-system","status":"publish","type":"page","link":"https:\/\/corona1.eu\/en\/grounding-control-system\/","title":{"rendered":"Grounding control system"},"content":{"rendered":"\n\n<p> applicable in explosion hazardous areas and are used to ground conductive elements of technological installations.<\/p>\n\n\n\n\n\n<p>Technical solutions of electrostatic grounding allow the discharge of electrostatic charges from tank cars, railroad tank cars, IBC tanks, metal containers, drums, carts and other technological equipment (e.g. mixers) or their instrumentation components, which can become electrified and pose a serious danger. A selection of them monitor grounding status in real time.<\/p>\n\n\n\n\n\n<div class=\"accordion-item\">\n    <div class=\"accordion__item-header collapsed\" data-toggle=\"collapse\" data-target=\"#collapse1p\" aria-expanded=\"false\">\n       <a class=\"accordion__item-title\" href=\"#\">Product groups<\/a>\n    <\/div><!-- \/.accordion-item-header -->\n\n    <div id=\"collapse1p\" class=\"collapse\" data-parent=\"#accordion\">\n        <div class=\"accordion__item-body\">\n            <p>\n               <b>There are two most important product groups:<\/b>\n            <\/p><ul>\n                <li>systems designed for monitoring and ongoing control of grounding status,<\/li>\n                <li>grounding clamps (also known as clamps, pliers, pincers, earthing clamps, crocodiles) equipped with\n                    single- or two-wire cables &#8211; used for dissipation of electrostatic charges.<\/li>\n            <\/ul>\n            <p><\/p>\n        <\/div><!-- \/.accordion-item-body -->\n\n    <\/div>\n<\/div>\n<div class=\"accordion-item\">\n    <div class=\"accordion__item-header collapsed\" data-toggle=\"collapse\" data-target=\"#collapse2p\" aria-expanded=\"false\">\n       <a class=\"accordion__item-title\" href=\"#\">The threat of static electricity in industrial plants<\/a>\n    <\/div><!-- \/.accordion-item-header -->\n\n    <div id=\"collapse2p\" class=\"collapse\" data-parent=\"#accordion\">\n        <div class=\"accordion__item-body\">\n            <p>\n               <b>Electrostatic discharge is one of the potential ignition sources of explosive atmospheres. In view of\n                    this hazard should not be ignored by plant services and business owners.\n                    By implementing appropriate electrostatic safeguards, the following can be avoided or reduced\n                    among others:<\/b>\n            <\/p><ul>\n                <li>the danger associated with the possibility of fire and\/or explosion in the industrial facility or\n                    on its premises (which can occur enough when the energy of the electrostatic discharge\n                    reaches a value at least comparable to the minimum ignition energy of the flammable substance\/agent\n                    (MEZ) occurring or likely to occur in the area),<\/li>\n                <li>disturbances in the course of ongoing technological processes affecting the quality of manufactured products\n                    products and resulting necessity of technological breaks generating additional costs,<\/li>\n                <li>mishaps endangering the health and life of plant personnel.<\/li>\n            <\/ul>\n            In view of the consequences of the above risks, the costs associated with the implementation of electrostatic protection are\n            negligible.\n           <p><\/p>\n        <\/div><!-- \/.accordion-item-body -->\n\n    <\/div>\n<\/div>\n<div class=\"accordion-item\">\n    <div class=\"accordion__item-header collapsed\" data-toggle=\"collapse\" data-target=\"#collapse3p\" aria-expanded=\"false\">\n       <a class=\"accordion__item-title\" href=\"#\">When is electrostatic discharge protection applied\n            electrostatic discharges?<\/a>\n    <\/div><!-- \/.accordion-item-header -->\n\n    <div id=\"collapse3p\" class=\"collapse\" data-parent=\"#accordion\">\n        <div class=\"accordion__item-body\">\n            <p>\n               <b>Electrostatic protection (a.k.a. anti-electrostatic, anti-static) measures are designed to\n                    are aimed at eliminating hazards arising from the generation and accumulation of electrostatic charge.\n                    In particular, they should be implemented in enterprises where there are zones of danger of\n                    explosion and which, among other things:<\/b>\n            <\/p><ul>\n                <li>implement processes such as, for example, batching, mixing, pouring, transferring products\n                    flammable,<\/li>\n                <li>receive explosive liquid substances or bulk materials (such as sugar,\n                    flour) via tanker trucks \/ dump trucks \/ railroad tank cars (processes of\n                    loading\/unloading).<\/li>\n            <\/ul>\n            We cooperate with both industrial services (including health and safety, fire protection, technological departments\n            representing the following industries: chemical, petrochemical, cosmetics, paints and varnishes, food, paper,\n            energy, electronics or printing plants), as well as with designers of industrial facilities.\n           <p><\/p>\n        <\/div><!-- \/.accordion-item-body -->\n\n    <\/div>\n<\/div>\n<div class=\"accordion-item\">\n    <div class=\"accordion__item-header collapsed\" data-toggle=\"collapse\" data-target=\"#collapse4p\" aria-expanded=\"false\">\n       <a class=\"accordion__item-title\" href=\"#\">Benefits of effective electrostatic protection<\/a>\n    <\/div><!-- \/.accordion-item-header -->\n\n    <div id=\"collapse4p\" class=\"collapse\" data-parent=\"#accordion\">\n        <div class=\"accordion__item-body\">\n            <p>\n            <\/p><ul>\n                <li>Protecting the health and lives of personnel during their duties by preventing accidents\n                    caused by electrostatic discharge phenomenon<\/li>\n                <li>Significant impact on the appropriate level of safety and working conditions<\/li>\n                <li>Protection of plant property by reducing the risk of ignition of flammable atmosphere as a result of the jump of an electrostatic spark\n                    electrostatic spark, the consequence of which can be a dramatic fire or explosion<\/li>\n                <li>Safety and reliability of processes carried out in the daily operation of enterprises\n                    industrial<\/li>\n                <li>Fulfillment of the obligation to implement protection against static electricity in potentially explosive atmospheres\n                    explosion, which results from the requirements of the ATEX Directive 2014\/34\/EU, ATEX USERS 199\/92\/EC and current\n                    national regulations<\/li>\n            <\/ul>\n            <p><\/p>\n        <\/div><!-- \/.accordion-item-body -->\n\n    <\/div>\n<\/div>\n\n\n\n\n\n<p><\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>applicable in explosion hazardous areas and are used to ground conductive elements of technological installations. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":823,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"kg_products_list_template_1.php","meta":{"pgc_sgb_lightbox_settings":"","footnotes":""},"categories":[34,9],"tags":[],"class_list":["post-822","page","type-page","status-publish","has-post-thumbnail","hentry","category-grounding-control-system","category-zprodukty"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Grounding control system | CORONA Service<\/title>\n<meta name=\"description\" content=\"Electrostatic grounding is a basic and mandatory measure for protection against static electricity in explosion hazard zones.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/corona1.eu\/en\/grounding-control-system\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Grounding control system | CORONA Service\" \/>\n<meta property=\"og:description\" content=\"Electrostatic grounding is a basic and mandatory measure for protection against static electricity in explosion hazard zones.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/corona1.eu\/en\/grounding-control-system\/\" \/>\n<meta property=\"og:site_name\" content=\"CORONA Service\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-29T07:44:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/corona1.eu\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/system_kontroli_uziemienia16x9.png\" \/>\n\t<meta property=\"og:image:width\" content=\"889\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/corona1.eu\\\/en\\\/grounding-control-system\\\/\",\"url\":\"https:\\\/\\\/corona1.eu\\\/en\\\/grounding-control-system\\\/\",\"name\":\"Grounding control system | CORONA Service\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/corona1.eu\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/corona1.eu\\\/en\\\/grounding-control-system\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/corona1.eu\\\/en\\\/grounding-control-system\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/corona1.eu\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2025\\\/08\\\/system_kontroli_uziemienia16x9.png\",\"datePublished\":\"2025-08-29T07:43:18+00:00\",\"dateModified\":\"2025-08-29T07:44:23+00:00\",\"description\":\"Electrostatic grounding is a basic and mandatory measure for protection against static electricity in explosion hazard zones.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/corona1.eu\\\/en\\\/grounding-control-system\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/corona1.eu\\\/en\\\/grounding-control-system\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/corona1.eu\\\/en\\\/grounding-control-system\\\/#primaryimage\",\"url\":\"https:\\\/\\\/corona1.eu\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2025\\\/08\\\/system_kontroli_uziemienia16x9.png\",\"contentUrl\":\"https:\\\/\\\/corona1.eu\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2025\\\/08\\\/system_kontroli_uziemienia16x9.png\",\"width\":889,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/corona1.eu\\\/en\\\/grounding-control-system\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/corona1.eu\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Grounding control system\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/corona1.eu\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/corona1.eu\\\/en\\\/\",\"name\":\"CORONA Service\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/corona1.eu\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Grounding control system | CORONA Service","description":"Electrostatic grounding is a basic and mandatory measure for protection against static electricity in explosion hazard zones.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/corona1.eu\/en\/grounding-control-system\/","og_locale":"en_US","og_type":"article","og_title":"Grounding control system | CORONA Service","og_description":"Electrostatic grounding is a basic and mandatory measure for protection against static electricity in explosion hazard zones.","og_url":"https:\/\/corona1.eu\/en\/grounding-control-system\/","og_site_name":"CORONA Service","article_modified_time":"2025-08-29T07:44:23+00:00","og_image":[{"width":889,"height":500,"url":"https:\/\/corona1.eu\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/system_kontroli_uziemienia16x9.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/corona1.eu\/en\/grounding-control-system\/","url":"https:\/\/corona1.eu\/en\/grounding-control-system\/","name":"Grounding control system | CORONA Service","isPartOf":{"@id":"https:\/\/corona1.eu\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/corona1.eu\/en\/grounding-control-system\/#primaryimage"},"image":{"@id":"https:\/\/corona1.eu\/en\/grounding-control-system\/#primaryimage"},"thumbnailUrl":"https:\/\/corona1.eu\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/system_kontroli_uziemienia16x9.png","datePublished":"2025-08-29T07:43:18+00:00","dateModified":"2025-08-29T07:44:23+00:00","description":"Electrostatic grounding is a basic and mandatory measure for protection against static electricity in explosion hazard zones.","breadcrumb":{"@id":"https:\/\/corona1.eu\/en\/grounding-control-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/corona1.eu\/en\/grounding-control-system\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/corona1.eu\/en\/grounding-control-system\/#primaryimage","url":"https:\/\/corona1.eu\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/system_kontroli_uziemienia16x9.png","contentUrl":"https:\/\/corona1.eu\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/system_kontroli_uziemienia16x9.png","width":889,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/corona1.eu\/en\/grounding-control-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/corona1.eu\/en\/"},{"@type":"ListItem","position":2,"name":"Grounding control system"}]},{"@type":"WebSite","@id":"https:\/\/corona1.eu\/en\/#website","url":"https:\/\/corona1.eu\/en\/","name":"CORONA Service","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/corona1.eu\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/pages\/822","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/comments?post=822"}],"version-history":[{"count":2,"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/pages\/822\/revisions"}],"predecessor-version":[{"id":825,"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/pages\/822\/revisions\/825"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/media\/823"}],"wp:attachment":[{"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/media?parent=822"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/categories?post=822"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/corona1.eu\/en\/wp-json\/wp\/v2\/tags?post=822"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}